28 lines
1.3 KiB
Markdown
28 lines
1.3 KiB
Markdown
# P_Rec_Annot Ortho DryRun
|
|
|
|
Date: 2026-08-03
|
|
|
|
Launcher Next executed the isolated `NextPilot` flow in `DryRun` mode. The
|
|
generated AutoCAD startup script contained one `NETLOAD` for the versioned
|
|
local entry assembly; no legacy bootstrap was used and no `/p` argument was
|
|
passed.
|
|
|
|
The actual Ortho drawing was `TestPipeOrtho.dwg`. `PHP_REC_ANNOT` ran twice,
|
|
`PXP-AAV` ran twice, and `PXP-OA` ran once. Each completed with Ortho detected,
|
|
one viewport, zero examined objects, zero planned operations, and no command
|
|
error. `DBMOD` was `0` both before and after the commands.
|
|
|
|
The Ortho sheet's `SelectAcPpRowIds` call raised `DLException: NotFound` in the
|
|
preceding attempt. The read adapter now treats that condition as an empty,
|
|
read-only result so it cannot fail a DryRun command. It does not yet map an
|
|
Ortho sheet back to source-model DataLinks rows; therefore successful source
|
|
Pipe discovery and a non-empty AnnotationPlan remain unverified.
|
|
|
|
After Plant 3D closed, Launcher Next reported `RolledBack`; the startup script,
|
|
version directory, current/previous pointers, and staging contents were absent.
|
|
|
|
The fixture SHA comparison found one changed project file: `Piping.dcf`.
|
|
Its last-write time predates the first DryRun command, so the observation cannot
|
|
be attributed to a P_Rec_Annot write. Nevertheless, project/DCF invariance is
|
|
not established by this run.
|