17 lines
1.2 KiB
Markdown
17 lines
1.2 KiB
Markdown
# Migration dashboard
|
|
|
|
The first real Plant 3D 2026 build is complete against the workstation assemblies (AutoCAD managed 25.1.0.0; Plant managed 17.0.60.1; AdWindows 5.2.1.1). Core remains Autodesk-free.
|
|
|
|
| Area | Status |
|
|
|---|---|
|
|
| `PHP_REC_ANNOT` | Registered real `CommandMethod`; primary diagnostic entry point |
|
|
| `PXP-AAV` | Registered real `CommandMethod`; diagnostic alias |
|
|
| `PXP-OA` | Registered real `CommandMethod`; diagnostic alias |
|
|
| Ribbon | Implemented with `Autodesk.Windows`; idempotent tab/panel guard |
|
|
| Adapter | Compiled against real 2026 assemblies |
|
|
| Bundle | Local smoke package built and checked for Autodesk DLL exclusion |
|
|
| Runtime | Not executed in AutoCAD/Plant process |
|
|
| Production deploy | NOT PERFORMED |
|
|
|
|
Fixed API assumptions: foundation-only lifecycle became `IExtensionApplication`; command descriptors became actual `CommandMethod` registrations; Plant project detection uses `PlantApplication.CurrentProject`; Ribbon uses `ComponentManager.Ribbon`, `RibbonTab`, `RibbonPanelSource`, and `RibbonButton`. Remaining blockers are runtime loading, Ortho API/data-link mapping, safe DWG transaction implementation, and golden fixture validation.
|