docs: record local Plant 3D Ortho DryRun
This commit is contained in:
@@ -0,0 +1,27 @@
|
||||
# P_Rec_Annot Ortho DryRun
|
||||
|
||||
Date: 2026-08-03
|
||||
|
||||
Launcher Next executed the isolated `NextPilot` flow in `DryRun` mode. The
|
||||
generated AutoCAD startup script contained one `NETLOAD` for the versioned
|
||||
local entry assembly; no legacy bootstrap was used and no `/p` argument was
|
||||
passed.
|
||||
|
||||
The actual Ortho drawing was `TestPipeOrtho.dwg`. `PHP_REC_ANNOT` ran twice,
|
||||
`PXP-AAV` ran twice, and `PXP-OA` ran once. Each completed with Ortho detected,
|
||||
one viewport, zero examined objects, zero planned operations, and no command
|
||||
error. `DBMOD` was `0` both before and after the commands.
|
||||
|
||||
The Ortho sheet's `SelectAcPpRowIds` call raised `DLException: NotFound` in the
|
||||
preceding attempt. The read adapter now treats that condition as an empty,
|
||||
read-only result so it cannot fail a DryRun command. It does not yet map an
|
||||
Ortho sheet back to source-model DataLinks rows; therefore successful source
|
||||
Pipe discovery and a non-empty AnnotationPlan remain unverified.
|
||||
|
||||
After Plant 3D closed, Launcher Next reported `RolledBack`; the startup script,
|
||||
version directory, current/previous pointers, and staging contents were absent.
|
||||
|
||||
The fixture SHA comparison found one changed project file: `Piping.dcf`.
|
||||
Its last-write time predates the first DryRun command, so the observation cannot
|
||||
be attributed to a P_Rec_Annot write. Nevertheless, project/DCF invariance is
|
||||
not established by this run.
|
||||
Reference in New Issue