AutoCAD/Plant launch chain
Confirmed static chain
User
-> All_Serv_Install.exe Form1
-> copy selected Plant 3D application folders to local Applications target
-> Process.Start(P_Serv_Starter.exe, five configured arguments)
-> P_Serv_Starter creates local _app_netload.lsp and copies launcher_starter.lsp
-> P_Serv_Starter starts C:\AutoCAD User Support\p3d-support\start_plant_3d.bat
-> [UNKNOWN: installed batch contents and auto-load registration]
-> Plant 3D startup
-> launcher_starter.lsp (when loaded)
-> local app_netload.lsp
-> _netload local Applications\P_Rec_Annot\OrthoLoader.dll
-> OrthoLoader Settings.xml -> sequential ._netload configured modules
The final two steps are confirmed by the prior P_Rec_Annot legacy audit. The activation of launcher_starter.lsp is not directly implemented in P_Serv_Starter: Program.cs:181 comments that acaddoc.lsp renames the generated file, while the copied LISP itself performs the rename and load. No matching installed acaddoc.lsp, batch file, or Applications directory existed on this workstation at audit time. Therefore automatic execution is UNKNOWN, not asserted.
Source evidence
| Claim | Evidence | Confidence |
|---|---|---|
| User-visible installer starts configured object | All_Serv_Install/Form1.cs:195-230 |
CONFIRMED |
Plant pattern object is P_Serv_Starter.exe |
All_Serv_Install/Settings.xml, Plant 3D pattern |
CONFIRMED |
| Five arguments include product, Applications target, settings, project and working directory | Settings.xml Plant pattern and P_Serv_Starter/Program.cs:12-23 |
CONFIRMED |
Bootstrap generates _app_netload.lsp |
P_Serv_Starter/Program.cs:58-182 |
CONFIRMED |
Generated DLL modules use AutoLISP _netload |
P_Serv_Starter/Program.cs:146-151 |
CONFIRMED |
| Bootstrap copies LISP and starts local batch file | P_Serv_Starter/Program.cs:202-216,49-54 |
CONFIRMED |
| Generated LISP is renamed, SupportPath updated and loaded | P_Serv_Starter/launcher_starter.lsp:74-96 |
CONFIRMED |
| Actual installed batch launches a specific Plant version | no installed batch was present | UNKNOWN |
Historical source-only alternative
All_Serv_Load/Addins/start_plant_3d.bat contains a direct AutoCAD 2019 command using /product PLNT3D /language "ru-RU", preceded by PlantCleaner and PnPPersistentCache cleanup. It is evidence only of that project's historical script; it is not evidence that current users start Plant 3D 2026 this way. No /ld, profile, LISP or script argument is present in that script.