build: resolve local plant 3d 2026 managed references
This commit is contained in:
@@ -1,4 +1,5 @@
|
|||||||
<Project>
|
<Project>
|
||||||
|
<Import Project="Local.Build.props" Condition="Exists('Local.Build.props')" />
|
||||||
<PropertyGroup>
|
<PropertyGroup>
|
||||||
<Nullable>enable</Nullable>
|
<Nullable>enable</Nullable>
|
||||||
<ImplicitUsings>enable</ImplicitUsings>
|
<ImplicitUsings>enable</ImplicitUsings>
|
||||||
@@ -9,5 +10,8 @@
|
|||||||
<AutoCAD2026ManagedDir Condition="'$(AutoCAD2026ManagedDir)' == '' and '$(Plant3D2026InstallDir)' != ''">$(Plant3D2026InstallDir)</AutoCAD2026ManagedDir>
|
<AutoCAD2026ManagedDir Condition="'$(AutoCAD2026ManagedDir)' == '' and '$(Plant3D2026InstallDir)' != ''">$(Plant3D2026InstallDir)</AutoCAD2026ManagedDir>
|
||||||
<Plant3D2026ManagedDir Condition="'$(Plant3D2026ManagedDir)' == '' and '$(Plant3D2026InstallDir)' != ''">$(Plant3D2026InstallDir)\PLNT3D</Plant3D2026ManagedDir>
|
<Plant3D2026ManagedDir Condition="'$(Plant3D2026ManagedDir)' == '' and '$(Plant3D2026InstallDir)' != ''">$(Plant3D2026InstallDir)\PLNT3D</Plant3D2026ManagedDir>
|
||||||
<Plant3D2026InstallDir Condition="'$(Plant3D2026InstallDir)' == '' and '$(AutoCAD2026ManagedDir)' != ''">$(AutoCAD2026ManagedDir)</Plant3D2026InstallDir>
|
<Plant3D2026InstallDir Condition="'$(Plant3D2026InstallDir)' == '' and '$(AutoCAD2026ManagedDir)' != ''">$(AutoCAD2026ManagedDir)</Plant3D2026InstallDir>
|
||||||
|
<Plant3D2026StandardInstallDir Condition="'$(Plant3D2026StandardInstallDir)' == ''">$(ProgramW6432)\Autodesk\AutoCAD 2026</Plant3D2026StandardInstallDir>
|
||||||
|
<AutoCAD2026ManagedDir Condition="'$(AutoCAD2026ManagedDir)' == '' and Exists('$(Plant3D2026StandardInstallDir)\AcMgd.dll')">$(Plant3D2026StandardInstallDir)</AutoCAD2026ManagedDir>
|
||||||
|
<Plant3D2026ManagedDir Condition="'$(Plant3D2026ManagedDir)' == '' and Exists('$(Plant3D2026StandardInstallDir)\PLNT3D\PnPProjectManagerMgd.dll')">$(Plant3D2026StandardInstallDir)\PLNT3D</Plant3D2026ManagedDir>
|
||||||
</PropertyGroup>
|
</PropertyGroup>
|
||||||
</Project>
|
</Project>
|
||||||
|
|||||||
@@ -1,5 +1,11 @@
|
|||||||
# Build
|
# Build
|
||||||
|
|
||||||
|
References resolve in this order: explicit `AutoCAD2026ManagedDir` and
|
||||||
|
`Plant3D2026ManagedDir`, an untracked `Local.Build.props`, then the validated
|
||||||
|
standard Plant 3D 2026 install directory. No Autodesk binary is copied into the
|
||||||
|
repository or bundle. If discovery does not find all required assemblies, pass
|
||||||
|
the explicit properties shown below.
|
||||||
|
|
||||||
The workstation has .NET SDK 8.0.423 and Autodesk AutoCAD Plant 3D 2026 installed. The paths are deliberately supplied at build time; no machine-specific Autodesk path is stored in project files.
|
The workstation has .NET SDK 8.0.423 and Autodesk AutoCAD Plant 3D 2026 installed. The paths are deliberately supplied at build time; no machine-specific Autodesk path is stored in project files.
|
||||||
|
|
||||||
Detected assembly inventory:
|