audit: document launcher source architecture
This commit is contained in:
@@ -0,0 +1,24 @@
|
||||
# LAUNCHER to P_Rec_Annot
|
||||
|
||||
## Proven loading contract
|
||||
|
||||
| Stage | Evidence | Finding | Confidence |
|
||||
|---|---|---|---|
|
||||
| Deployment selection | `All_Serv_Install/Settings.xml`; `download_lists/download_list_plant.xml` | `P_Rec_Annot` is an installer plugin catalog; its configured install file is `OrthoLoader.dll`. | CONFIRMED |
|
||||
| Local target | Plant configuration target | P_Rec_Annot is intended to be copied under `C:\AutoCAD User Support\Applications\P_Rec_Annot`. | CONFIRMED |
|
||||
| Bootstrap selection | installer Plant pattern object/arguments | `All_Serv_Install` invokes `P_Serv_Starter.exe` after install selection. | CONFIRMED |
|
||||
| Generated first load | `P_Serv_Starter/Program.cs:140-174` | For each installed DLL catalog, generated LISP emits `(command "_netload" attribute)`. Therefore `OrthoLoader.dll` is loaded from the local Applications path when its catalog exists. | CONFIRMED |
|
||||
| Generated LISP activation | `launcher_starter.lsp:74-96` | It renames `_app_netload.lsp`, adds Applications to SupportPath and `(load ...)`s `app_netload.lsp`. | CONFIRMED |
|
||||
| Automatic LISP invocation | source comment in `Program.cs:181`; no installed startup file | `acaddoc.lsp` is named by a comment, but its installed content and registration were not available. | UNKNOWN |
|
||||
| Secondary module load | legacy audit, `OrthoLoader.Ribbon.Initialize` / `OrthoLoader.Initialize` | OrthoLoader reads adjacent Settings.xml and sequentially calls `._netload` for 20 configured modules. | CONFIRMED |
|
||||
|
||||
## P_Rec_Annot-specific implication
|
||||
|
||||
The historic contract is not a direct network `NETLOAD`. It is a local synchronized application directory followed by a generated, per-session AutoLISP loader. A generated LISP includes the Plant project path in its first comment and conditionally emits loads only for existing local plugin catalogs. New code must not reproduce that behavior before deciding whether it is compatible, necessary and safe for Plant 3D 2026.
|
||||
|
||||
The prior legacy audit established that `OrthoLoader.dll` is the initial assembly for P_Rec_Annot. This launcher audit establishes how the installer/bootstrap is intended to make that assembly loadable. Neither audit proves the deployed local files existed or auto-loaded on this workstation.
|
||||
|
||||
## Integration recommendation
|
||||
|
||||
Use one versioned, locally synchronized entry artifact only after a compatibility decision. The minimal pilot should retain the existing installer catalog/target contract, make the bootstrap load exactly one new entry assembly, and use an explicitly reviewed startup mechanism. Do not rely on an unproven AppLoader bundle or add new global `TRUSTEDPATHS`/profile mutations. The generated loader and any project-path comment are legacy behavior, not requirements for the new P_Rec_Annot until runtime validation establishes a need.
|
||||
|
||||
Reference in New Issue