test: add controlled Plant 3D 2026 runtime smoke mode
This commit is contained in:
@@ -0,0 +1,79 @@
|
||||
using System.Diagnostics;
|
||||
using System.Text.Json;
|
||||
using Autodesk.AutoCAD.ApplicationServices;
|
||||
using Autodesk.ProcessPower.PlantInstance;
|
||||
|
||||
namespace PRecAnnot.Plant3D2026;
|
||||
|
||||
internal static class RuntimeDiagnostics
|
||||
{
|
||||
private static readonly object Gate = new();
|
||||
private static readonly string LogDirectory = Path.Combine(
|
||||
Environment.GetFolderPath(Environment.SpecialFolder.LocalApplicationData),
|
||||
"Promhimproekt", "PRecAnnot2026", "Logs");
|
||||
|
||||
public static string RuntimeMode => Environment.GetEnvironmentVariable("P_REC_ANNOT_RUNTIME_MODE") ?? "Normal";
|
||||
|
||||
public static void Write(
|
||||
string eventType,
|
||||
string level = "INFO",
|
||||
string? operationId = null,
|
||||
string? commandName = null,
|
||||
string? resultStatus = null,
|
||||
System.Exception? exception = null,
|
||||
Document? document = null,
|
||||
IReadOnlyDictionary<string, object?>? details = null)
|
||||
{
|
||||
try
|
||||
{
|
||||
var payload = new Dictionary<string, object?>(StringComparer.Ordinal)
|
||||
{
|
||||
["Timestamp"] = DateTimeOffset.UtcNow,
|
||||
["Level"] = level,
|
||||
["OperationId"] = operationId,
|
||||
["EventType"] = eventType,
|
||||
["AssemblyVersion"] = typeof(EntryPoint).Assembly.GetName().Version?.ToString(),
|
||||
["AutoCADVersion"] = typeof(Document).Assembly.GetName().Version?.ToString(),
|
||||
["PlantVersion"] = typeof(PlantApplication).Assembly.GetName().Version?.ToString(),
|
||||
["ProcessId"] = Environment.ProcessId,
|
||||
["ThreadId"] = Environment.CurrentManagedThreadId,
|
||||
["ApartmentState"] = Thread.CurrentThread.GetApartmentState().ToString(),
|
||||
["ActiveDocumentName"] = SafeDocumentName(document),
|
||||
["CommandName"] = commandName,
|
||||
["ResultStatus"] = resultStatus,
|
||||
["ExceptionType"] = exception?.GetType().FullName,
|
||||
["ExceptionMessage"] = exception?.Message,
|
||||
["StackTrace"] = level.Equals("ERROR", StringComparison.OrdinalIgnoreCase) ? exception?.StackTrace : null,
|
||||
["RuntimeMode"] = RuntimeMode
|
||||
};
|
||||
|
||||
if (details is not null)
|
||||
foreach (var item in details) payload[item.Key] = item.Value;
|
||||
|
||||
var line = JsonSerializer.Serialize(payload) + Environment.NewLine;
|
||||
lock (Gate)
|
||||
{
|
||||
Directory.CreateDirectory(LogDirectory);
|
||||
File.AppendAllText(Path.Combine(LogDirectory, "runtime.jsonl"), line);
|
||||
}
|
||||
}
|
||||
catch
|
||||
{
|
||||
// Runtime diagnostics must never prevent AutoCAD command execution.
|
||||
}
|
||||
}
|
||||
|
||||
private static string? SafeDocumentName(Document? document)
|
||||
{
|
||||
try { return document is null ? null : Path.GetFileName(document.Name); }
|
||||
catch { return null; }
|
||||
}
|
||||
}
|
||||
|
||||
internal sealed class SmokeWriteBlockedException() : InvalidOperationException("SMOKE_WRITE_BLOCKED");
|
||||
|
||||
internal static class SmokeGuard
|
||||
{
|
||||
public static bool IsSmoke => string.Equals(RuntimeDiagnostics.RuntimeMode, "Smoke", StringComparison.OrdinalIgnoreCase);
|
||||
public static void EnsureReadOnly() { if (IsSmoke) throw new SmokeWriteBlockedException(); }
|
||||
}
|
||||
Reference in New Issue
Block a user