test: add controlled Plant 3D 2026 runtime smoke mode
This commit is contained in:
@@ -0,0 +1,26 @@
|
||||
{
|
||||
"product": "Autodesk AutoCAD Plant 3D 2026",
|
||||
"manualNetload": true,
|
||||
"bundleLoaded": true,
|
||||
"automaticAppLoaderChecked": false,
|
||||
"smokeModeConfirmedByOperator": true,
|
||||
"observedCommandLogRuntimeMode": "Normal",
|
||||
"assemblyInitializeCountObserved": 1,
|
||||
"commands": {
|
||||
"PHP_REC_ANNOT": { "registered": true, "executed": true, "usageEvents": 1, "result": "PreflightAccepted" },
|
||||
"PXP-AAV": { "registered": true, "executed": true, "usageEvents": 1, "result": "PreflightAccepted" },
|
||||
"PXP-OA": { "registered": true, "executed": true, "usageEvents": 1, "result": "PreflightAccepted" }
|
||||
},
|
||||
"ribbon": { "created": true, "duplicateCheckedExhaustively": false },
|
||||
"plantContext": { "projectDetected": true, "projectDisplayName": "DefaultProject", "observedOrthoDetected": false, "dataLinksAvailable": true },
|
||||
"writesBlocked": true,
|
||||
"dbmodChecked": false,
|
||||
"dwgModified": false,
|
||||
"dcfModified": false,
|
||||
"projectXmlModified": false,
|
||||
"telemetryEventsExpected": 3,
|
||||
"telemetryEventsActual": 3,
|
||||
"unhandledExceptions": 0,
|
||||
"temporaryInstallationRemoved": true,
|
||||
"productionDeploy": false
|
||||
}
|
||||
@@ -0,0 +1,31 @@
|
||||
# Plant 3D 2026 runtime smoke results
|
||||
|
||||
## Scope
|
||||
|
||||
The smoke test used a temporary per-user bundle installation only. Production deploy was not performed. The temporary installation was removed after AutoCAD closed.
|
||||
|
||||
## Confirmed
|
||||
|
||||
- Manual `NETLOAD` loaded the P_Rec_Annot entry assembly in AutoCAD Plant 3D 2026.
|
||||
- `PHP_REC_ANNOT`, `PXP-AAV`, and `PXP-OA` were accepted by the command line.
|
||||
- The active Plant project was detected as `DefaultProject`.
|
||||
- The user confirmed Smoke mode behavior and no DWG mutation during the manual smoke interaction.
|
||||
- The runtime log contains one assembly initialization and one normal termination for the observed process.
|
||||
- The runtime log records Ribbon creation with status `Created`.
|
||||
- The runtime log records exactly one `CommandUsageEvent` for each of the three commands.
|
||||
- The observed Plant context reported `DataLinksAvailable=true` and `IsOrthoDrawing=false` for `Floor Plan Sample.dwg`.
|
||||
- No unhandled exception was reported in the captured runtime log.
|
||||
|
||||
## Not confirmed
|
||||
|
||||
- Automatic AppLoader loading without `NETLOAD` was not tested.
|
||||
- DBMOD and byte-level DWG/DCF/Project.xml comparisons were not captured by the smoke evidence.
|
||||
- Ribbon duplicate behavior across workspace/document lifecycle was not exhaustively tested.
|
||||
- A command invocation logged as `RuntimeMode=Smoke` is not present in the captured JSONL; the three detailed command records have `RuntimeMode=Normal`.
|
||||
|
||||
## Evidence handling
|
||||
|
||||
The detailed runtime JSONL remains local under `%LOCALAPPDATA%\Promhimproekt\PRecAnnot2026\Logs\` and is not committed. No DWG, DCF, Project.xml, Autodesk DLL, user identity, project path, or full local runtime path is included in the repository.
|
||||
|
||||
Temporary installation: PERFORMED AND REMOVED.
|
||||
Production deploy: NOT PERFORMED.
|
||||
Reference in New Issue
Block a user